<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">vestar</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник аритмологии</journal-title><trans-title-group xml:lang="en"><trans-title>Journal of Arrhythmology</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1561-8641</issn><issn pub-type="epub">2658-7327</issn><publisher><publisher-name>НАО «Инкарт»</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">vestar-474</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОРИГИНАЛЬНЫЕ ИССЛЕДОВАНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ORIGINAL ARTICLES</subject></subj-group></article-categories><title-group><article-title>ОЦЕНКА ПОРОГОВОЙ ВЕЛИЧИНЫ И АВТОМАТИЧЕСКАЯ РЕГУЛИРОВКА ЭНЕРГИИ ИМПУЛЬСА ПРЕДСЕРДНОГО КАНАЛА КАРДИОСТИМУЛЯТОРА ПРИ ДВУХКАМЕРНОЙ ЭЛЕКТРОСТИМУЛЯЦИИ СЕРДЦА</article-title><trans-title-group xml:lang="en"><trans-title>THRESHOLD EVALUATION AND AUTOMATED ADJUSTMENT OF IMPULSE ENERGY OF THE PACEMKER ATRIAL CHANNEL IN DUAL CHAMBER CARDIAC PACING</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Идов</surname><given-names>Э. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Idov</surname><given-names>E. M.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Молодых</surname><given-names>С. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Molodykh</surname><given-names>S. V.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Неминущий</surname><given-names>Н. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Neminushchiy</surname><given-names>N. M.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-3"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Беляев</surname><given-names>О. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Belyaev</surname><given-names>O. V.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru">ГОУ ВПО «Уральская Государственная медицинская академия», Екатеринбург<country>Россия</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru">МУЗ «Центральная городская больница №4» Нижний Тагил<country>Россия</country></aff></aff-alternatives><aff-alternatives id="aff-3"><aff xml:lang="ru">ГОУВПО «Московскаямедицинская академия имениИ.М.Сеченова», Москва<country>Россия</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2010</year></pub-date><pub-date pub-type="epub"><day>22</day><month>09</month><year>2020</year></pub-date><volume>61</volume><issue>61</issue><fpage>46</fpage><lpage>51</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Идов Э.М., Молодых С.В., Неминущий Н.М., Беляев О.В., 2020</copyright-statement><copyright-year>2020</copyright-year><copyright-holder xml:lang="ru">Идов Э.М., Молодых С.В., Неминущий Н.М., Беляев О.В.</copyright-holder><copyright-holder xml:lang="en">Idov E.M., Molodykh S.V., Neminushchiy N.M., Belyaev O.V.</copyright-holder><license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://vestar.elpub.ru/jour/article/view/474">https://vestar.elpub.ru/jour/article/view/474</self-uri><abstract><p>С целью оценки клинических результатов длительного применения у больных симптомной брадикардией имплантируемых двухкамерных кардиостимуляторов, оснащенных алгоритмом Atrial Capture Management обследован и прооперирован 31 больной (16 мужчин и 15 женщин в возрасте от 41 до 84 лет, средний возраст 66,4±1,9 лет) с симптомной брадикардией на фоне синдрома слабости синусового узла или атриовентрикулярной блокады.</p></abstract><trans-abstract xml:lang="en"><p>To assess the clinical data of the long-term dual-chamber cardiac pacing with the Atrial Capture Management algorithm in patients with symptomatic bradycardia, 31 patients aged 66.4±1.9 year (16 men, 15 women; age 41 84 years) with symptomatic bradycardia at the background of the sick sinus syndrome or atrio-ventricular block were examined.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>двухкамерные электрокардиостимуляторы</kwd><kwd>порог стимуляции</kwd><kwd>управление предсердным захватом</kwd><kwd>синдром слабости синусового узла</kwd><kwd>атриовентрикулярная блокада</kwd></kwd-group><kwd-group xml:lang="en"><kwd>dual-chamber cardiac pacemakers</kwd><kwd>pacing threshold</kwd><kwd>control of atrial capture</kwd><kwd>sick sinus syndrome</kwd><kwd>atrio-ventricular block</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Бокерия Л.А., Ревишвили А.Ш., Давтян К.В. Электрокардиостимуляция при брадиаритмиях. В кн. Руководство по нарушениям ритма сердца. Под ред. Е.И. Чазова, С.П. Голицына. - М.:, ГЭОТАР-Медиа, 2008 - С. 273-307</mixed-citation><mixed-citation xml:lang="en">Бокерия Л.А., Ревишвили А.Ш., Давтян К.В. Электрокардиостимуляция при брадиаритмиях. В кн. Руководство по нарушениям ритма сердца. Под ред. Е.И. Чазова, С.П. Голицына. - М.:, ГЭОТАР-Медиа, 2008 - С. 273-307</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Вагнер Е.А., Протопопов В.В., Молодых С.В. Исследование порога возбудимости миокарда при постоянной электростимуляции желудочков сердца // Грудная и сердечно-сосудистая хирургия. - 1994. - № 2. - С. 33-37.</mixed-citation><mixed-citation xml:lang="en">Вагнер Е.А., Протопопов В.В., Молодых С.В. Исследование порога возбудимости миокарда при постоянной электростимуляции желудочков сердца // Грудная и сердечно-сосудистая хирургия. - 1994. - № 2. - С. 33-37.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Жданов А.М., Александров А.Н., Фролов В.М. и др. Значение детекции амплитуды R-волны в оптимизации автоматического измерения порога стимуляции и регулирования амплитуды стимулирущего импульса // Вестник аритмологии. - 2005. - №41. - С. 17-20</mixed-citation><mixed-citation xml:lang="en">Жданов А.М., Александров А.Н., Фролов В.М. и др. Значение детекции амплитуды R-волны в оптимизации автоматического измерения порога стимуляции и регулирования амплитуды стимулирущего импульса // Вестник аритмологии. - 2005. - №41. - С. 17-20</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Идов Э.М., Молодых С.В., Беляев О.В. Автоматическое измерение пороговой величины и регулировка энергии импульса предсердного канала при двухкамерной электростимуляции сердца // Сердечно-сосудистые заболевания. Бюллетень НЦССХ им. А.Н.Бакулева РАМН. 2009. №6. Сборн. тез. докладов 15-го Всероссийского сьезда серд.-сосуд. хирургов. - С. 93.</mixed-citation><mixed-citation xml:lang="en">Идов Э.М., Молодых С.В., Беляев О.В. Автоматическое измерение пороговой величины и регулировка энергии импульса предсердного канала при двухкамерной электростимуляции сердца // Сердечно-сосудистые заболевания. Бюллетень НЦССХ им. А.Н.Бакулева РАМН. 2009. №6. Сборн. тез. докладов 15-го Всероссийского сьезда серд.-сосуд. хирургов. - С. 93.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Клинические рекомендации по проведению электрофизиологических исследований, катетерной аблации и применению имплантируемых антиаритмических устройств. / Под ред. Л.А. Бокерия, А.Ш. Ревишвили, Р.Г. Оганова. - М.: Асконлайн, 2009 - 304 с.</mixed-citation><mixed-citation xml:lang="en">Клинические рекомендации по проведению электрофизиологических исследований, катетерной аблации и применению имплантируемых антиаритмических устройств. / Под ред. Л.А. Бокерия, А.Ш. Ревишвили, Р.Г. Оганова. - М.: Асконлайн, 2009 - 304 с.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Клиническая аритмология. / Под ред. А.В. Ардашева. - М.: «Медпрактика-М», 2009. - 1220 с.</mixed-citation><mixed-citation xml:lang="en">Клиническая аритмология. / Под ред. А.В. Ардашева. - М.: «Медпрактика-М», 2009. - 1220 с.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Biffi M, Spitali G, Silvetti M. et al. Atrial threshold variability: implications for automatic atrial stimulation algorithms // PACE. - 2007. - Vol.30. - №10. - P. 1445-1454.</mixed-citation><mixed-citation xml:lang="en">Biffi M, Spitali G, Silvetti M. et al. Atrial threshold variability: implications for automatic atrial stimulation algorithms // PACE. - 2007. - Vol.30. - №10. - P. 1445-1454.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Boriani G, Biffi M, Branzi A. et al. Benefits in projected pacemaker longevity and in pacing related costs conferred by automatic threshold tracking // PACE. - 2000. - Vol.23. - №11. - P. 1783-1787.</mixed-citation><mixed-citation xml:lang="en">Boriani G, Biffi M, Branzi A. et al. Benefits in projected pacemaker longevity and in pacing related costs conferred by automatic threshold tracking // PACE. - 2000. - Vol.23. - №11. - P. 1783-1787.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Boriani G, Biffi M, Cannom D. et al. Atrial evoked response integral for automatic capture verification in atrial pacing // PACE. - 2003. - Vol.26. - №2. - P. 248-252.</mixed-citation><mixed-citation xml:lang="en">Boriani G, Biffi M, Cannom D. et al. Atrial evoked response integral for automatic capture verification in atrial pacing // PACE. - 2003. - Vol.26. - №2. - P. 248-252.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Butter C, Hartung W, Kay G. et al. Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers // J. Cardiovasc. Electrophysiol. - 2001. - Vol.12. - №10. - P. 1104 -1108.</mixed-citation><mixed-citation xml:lang="en">Butter C, Hartung W, Kay G. et al. Clinical validation of new pacing-sensing configurations for atrial automatic capture verification in pacemakers // J. Cardiovasc. Electrophysiol. - 2001. - Vol.12. - №10. - P. 1104 -1108.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Butter C., Zhang G., Seifert M. et al. Effect of atrial lead position on atrial automatic capture verification // PACE. - 2008. - Vol.31. - №10. - P.1118-1124</mixed-citation><mixed-citation xml:lang="en">Butter C., Zhang G., Seifert M. et al. Effect of atrial lead position on atrial automatic capture verification // PACE. - 2008. - Vol.31. - №10. - P.1118-1124</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Dohrmann ML, Goldschlager NF. Myocardial stimulation threshold in patients with cardiac pacemakers: effect of physiologic variables, pharmacologic agents, and lead electrodes // Cardiol. Clin. - 1985. - Vol.3. - №3. - P.527-537.</mixed-citation><mixed-citation xml:lang="en">Dohrmann ML, Goldschlager NF. Myocardial stimulation threshold in patients with cardiac pacemakers: effect of physiologic variables, pharmacologic agents, and lead electrodes // Cardiol. Clin. - 1985. - Vol.3. - №3. - P.527-537.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Duru F, Bauersfeld U, Schuller H, Candinas R. Threshold tracking pacing based on beat by beat evoked response detection: clinical benefits and potential problems // J. Interv. Card. Electrophysiol. - 2000. - Vol. 4. - №4. - Р.511-522.</mixed-citation><mixed-citation xml:lang="en">Duru F, Bauersfeld U, Schuller H, Candinas R. Threshold tracking pacing based on beat by beat evoked response detection: clinical benefits and potential problems // J. Interv. Card. Electrophysiol. - 2000. - Vol. 4. - №4. - Р.511-522.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Kusumoto F., Goldschlager N. (eds). Cardiac pacing for the dinician. Springer Science, NY. - 2008. - 744pp.</mixed-citation><mixed-citation xml:lang="en">Kusumoto F., Goldschlager N. (eds). Cardiac pacing for the dinician. Springer Science, NY. - 2008. - 744pp.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Livingston AR, Callaghan FJ, Byrd C. et al. Atrial capture detection with endocardial electrodes // PACE. - 1988. - Vol.11. - №11, Pt 2. - Р. 1770-1776.</mixed-citation><mixed-citation xml:lang="en">Livingston AR, Callaghan FJ, Byrd C. et al. Atrial capture detection with endocardial electrodes // PACE. - 1988. - Vol.11. - №11, Pt 2. - Р. 1770-1776.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Medtronic Sensia DR manual. Minneapolis , USA. - 2008. - 214 pp.</mixed-citation><mixed-citation xml:lang="en">Medtronic Sensia DR manual. Minneapolis , USA. - 2008. - 214 pp.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Neuzner J, Schwarz T, Sperzel J. Pacemaker automaticity // Am. J. Cardiol. - 2000. - Vol.86. - Supplement A. - P.104K-110K.</mixed-citation><mixed-citation xml:lang="en">Neuzner J, Schwarz T, Sperzel J. Pacemaker automaticity // Am. J. Cardiol. - 2000. - Vol.86. - Supplement A. - P.104K-110K.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Rueter J, Heynen H, Meisel E et al. Automatic measurement of atrial pacing thresholds by AV conduction // PACE. - 2000. - Vol.23. - №4. Pt.II. - Р.658.</mixed-citation><mixed-citation xml:lang="en">Rueter J, Heynen H, Meisel E et al. Automatic measurement of atrial pacing thresholds by AV conduction // PACE. - 2000. - Vol.23. - №4. Pt.II. - Р.658.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Sheldon T, Nelson L, Vatterott P, Mead H. Atrial threshold measurement using atrial chamber reset method // PACE. - 2000. - Vol.23. - №4. Pt.II. - Р.634.</mixed-citation><mixed-citation xml:lang="en">Sheldon T, Nelson L, Vatterott P, Mead H. Atrial threshold measurement using atrial chamber reset method // PACE. - 2000. - Vol.23. - №4. Pt.II. - Р.634.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Silvetti M, De Santis A, Marcora S. et al. Circadian pattern of atrial pacing threshold in the young // Europace. - 2008. - Vol.10. - №2. - Р. 147-150.</mixed-citation><mixed-citation xml:lang="en">Silvetti M, De Santis A, Marcora S. et al. Circadian pattern of atrial pacing threshold in the young // Europace. - 2008. - Vol.10. - №2. - Р. 147-150.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Sperzel J, Milasinovic G, Smith T. et al. Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: clinical experience with atrial capture management // Heart Rhythm. - 2005. - Vol.2. - №10. - Р.1203-1210.</mixed-citation><mixed-citation xml:lang="en">Sperzel J, Milasinovic G, Smith T. et al. Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: clinical experience with atrial capture management // Heart Rhythm. - 2005. - Vol.2. - №10. - Р.1203-1210.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Sutten R, Froehlig G, de Voogt W. et al. Reduction of the pace polarization artifact for capture detection applications by a tri-phasic stimulation pulse // Europace. - 2004. - Vol. 6. - № 6. - Р. 570-579.</mixed-citation><mixed-citation xml:lang="en">Sutten R, Froehlig G, de Voogt W. et al. Reduction of the pace polarization artifact for capture detection applications by a tri-phasic stimulation pulse // Europace. - 2004. - Vol. 6. - № 6. - Р. 570-579.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Vonk B., van Oort G. New method of atrial and ventricular capture detection // PACE. - 1998. - Vol. 21. - № 1, Pt 2. - P. 217-222</mixed-citation><mixed-citation xml:lang="en">Vonk B., van Oort G. New method of atrial and ventricular capture detection // PACE. - 1998. - Vol. 21. - № 1, Pt 2. - P. 217-222</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Wood M. Automated pacemaker function // Cardiol. Clin. - 2000. - Vol.18. - №2. - Р. 177-191.</mixed-citation><mixed-citation xml:lang="en">Wood M. Automated pacemaker function // Cardiol. Clin. - 2000. - Vol.18. - №2. - Р. 177-191.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
