Preview

Journal of Arrhythmology

Advanced search

HEART RATE VARIABILITY AND CHOICE OF RATE-ADAPTIVE SENSOR IN PATIENTS WITH BRADYCARDIA-TACHYCARDIA SYNDROME

https://doi.org/ 10.25760/VA-2018-93-5-16.

Abstract

To assess baseline heart rate variability parameters which could correlate with the choice of an optimal algorithm of rate adaptation, 138 patients with bradycardia-tachycardia with indications to pacemaker implantation were assessed.

About the Authors

A. Sh. Revishvili
Институт хирургии им. А.В. Вишневского
Russian Federation


K. V. Davtyan
Национальный медицинский исследовательский центр профилактической медицины
Russian Federation


S. N. Krivolapov
Научно-исследовательский кардиологии, Томский национальный исследовательский медицинский центр Российской академии наук
Russian Federation


S. F. Sokolov
Национальный медицинский исследовательский центр кардиологии МЗ РФ
Russian Federation


N. N. Lomidze
Институт хирургии им. А.В. Вишневского
Russian Federation


A. A. Nechepurenko
Федеральный центр сердечнососудистой хирургии
Russian Federation


E. N. Okhotina
Самарский областной клинический кардиологический диспансер
Russian Federation


S. P. Mikhaylov
Свердловская областная клиническая больница № 1
Russian Federation


E. A. Artyukhina
Институт хирургии им. А.В. Вишневского
Russian Federation


R. E. Batalov
Научно-исследовательский кардиологии, Томский национальный исследовательский медицинский центр Российской академии наук
Russian Federation


D. S. Lebedev
Национальный медицинский исследовательский центр имени В.А. Алмазова МЗ РФ
Russian Federation


I. S. Sagitov
Республиканский кардиологический центр, Уфа
Russian Federation


D. N. Khomutinin
Областная клиническая больница, Тюмень
Russian Federation


References

1. Vardas P.E., Auricchio A., Blanc J.J. et al. Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association. Eur Heart J 2007; 28: 2256-95.

2. Coenen M., Malinowski K, Spitzer W. et al. Closed loop stimulation and accelerometer-based rate adaptation: results of the PROVIDE study. Europace 2008; 10(3): 327-33.

3. Schaldach M., Ebner E., Hutten H., et al. Right ventricular conductance to establish closed-loop pacing. Eur Heart J 1992; 13 Suppl. E: 104-12.

4. Schaldach M., Urbaszek A., Ströbel J., Heublein B. Rateadaptive pacing using a closed-loop stimulation, autonomic nervous system controlled pacemaker. J HK Coll Cardiol 1995; 3: 22-32.

5. Puglisi A., Altamura G., Capestro F. et al. Impact of Closed-Loop Stimulation, overdrive pacing, DDDR pacing mode on atrial tachyarrhythmia burden in Brady-Tachy Syndrome. A randomized study. Eur Heart J 2003; 24: 1952-61.

6. Puglisi A., Favale S., Scipione P. et al. Overdrive versus conventional or closed-loop rate modulation pacing in the prevention of atrial tachyarrhythmias in Brady-Tachy syndrome: on behalf of the Burden II Study Group. PACE 2008; 31: 1443-55.

7. Coumel P. Clinical Approach to Paroxysmal Atrial Fibrillation. Clin Cardiol 1990; 13: 209-12.

8. Ревишвили А.Ш., Рзаев Ф.Г., Джорджикия Т.Р. и др. Фибрилляция предсердий у пациентов молодого возраста. Анналы Аритмологии 2007; № 3: 22-27.

9. Bettoni M., Zimmermann M. Autonomic tone variations before the onset of paroxysmal atrial fibrillation. Circulation 2002; 105: 2753-9.

10. Heart rate variability. Standards of measurement, physiological interpretation, and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Eur Heart J 1996; 17: 354-81.

11. Баевский Р.М., Иванов Г.Г., Чирейкин Л.В. и др. Анализ вариабельности сердечного ритма при использовании различных электрокардиографических систем (методические рекомендации). Вестник аритмологии 2001; № 24: 65-87.

12. Bingeli C., Duru F., Candinas R., et al. Autonomic nervous system-controlled cardiac pacing: a comparison between intracardiac impedance signal and muscle sympathetic nerve activity. Pacing Clin Electrophysiol 2000; 23: 1632-1637.

13. Santini M., Ricci R., Pignalberi C., et al. Effect of autonomic nervous stressors on rate control in pacemaker using ventricular impedance signal. Pacing Clin Electrophysiol 2004; 27: 24-32.

14. Occhetta E., Bortnik M., Audoglio R., Vassanelli C. for the INVASY Study Investigators. Closed loop stimulation in prevention of vasovagal syncope. Inotropy controlled pacing in vasovagal syncope (INVASY): a multicentre randomized, single blind, controlled study. Europace 2004; 6: 6 538-547.

15. Lindovska M., Kamenik L., Pollock B. et al. Clinical observations with Closed Loop Stimulation pacemakers in a large patient cohort: the CYLOS routine documentation registry (RECORD). Europace 2012; 14: 1587-95.

16. Moser M., et al. Heart rate variability as a prognostic tool in cardiology. A contribution to the problem from a theoretical point of view. Circulation 1994; 90 (2): 10791082.

17. Löllgen H. Herzfrequenzvariabilität. Deutsches Ärzteblatt. 1999; 96 (31-32): A-2023-A-2029.

18. Censi F., Calcagnini G., D’Alessandro M., et al. Heart rate and blood pressure variability in patients implanted with rate-responsive pacemaker. Proceedings of the 26th Annual International Conference of the IEEE EMBS, San Francisco, CA, USA, September 1-5, 2004; 6: 3949-3952.

19. Quaglione R., Calcagnini G., Censi F., et al. Effect of pacemaker rate-adaptation on 24 h beat-to-beat heart rate and blood pressure profiles. Europace 2005 7(4): 366-373.

20. Drago F., Silvetti MS, De Santis A., et al. Rate-adapting pacing in a 7-year-old boy using ventricular contractility information. Pediatrics International 2008; 50 (1): 127129.

21. А.Ш. Ревишвили, И.В. Антонченко, А.В. Ардашев, и др. Рекомендации Всероссийского научного общества специалистов по клинической электрофизиологии, аритмологии и кардиостимуляции по проведению клинических электрофизиологических исследований, катетерной абляции и имплантации антиаритмических устройств. - Москва, 2005, 238 с.

22. Authors/Task Force Members, Vardas P.E., Auricchio A., Blanc J-J., et al. Guidelines for cardiac pacing and cardiac resynchronization therapy. European Heart Journal 2007; 28 (18): 2256-2295.

23. Sprent P., Smeeton N.C. Applied nonparametric statistical methods (3rd Edition). London: Chapman & Hall/CRC; 2001.

24. Bortz J., Lienert G.A. Kurzgefasste Statistik für die klinische Forschung (3. Auflage); 2008. Heidelberg: Springer Medizin Verlag, page 67 - from Sprent P., Smeeton N.C. Applied nonparametric statistical methods (3rd Edn.); 2001. London: Chapman & Hill, CRC 2001.

25. Akselrod S., Gordon D., Ubel F.A. et al. Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control. Science 1981; 213 (4504): 220-222.

26. Taylor J.A., Eckberg D.L. Fundamental relations between short-term RR interval and arterial pressure oscillations in humans. Circulation 1996; 93: 1527-32.

27. Goldstein D.S., Bentho O., Park M.Y., Sharabi Y. Low-frequency power of heart rate variability is not a measure of cardiac sympathetic tone but may be a measure of modulation of cardiac autonomic outflows by baroreflexes. Exp Physiol 2011; 96: 1255-61.

28. Guasti L., Mainardi L.T., Baselli G. et al. Components of arterial systolic pressure and RR-interval oscillation spectra in a case of baroreflex failure, a human open-loop model of vascular control. J Hum Hypertens 2010; 24: 417-26.

29. Notarius C.F., Butler G.C., Ando S. et al. Dissociation between microneurographic and heart rate variability estimates of sympathetic tone in normal subjects and patients with heart failure. Clin Sci (Lond) 1999; 96: 557-565.

30. Piccirillo G., Ogawa M., Song J. et al. Power spectral analysis of heart rate variability and autonomic nervous system activity measured directly in healthy dogs and dogs with tachycardia-induced heart failure. Heart Rhythm 2009; 6: 546-552.


Review

For citations:


Revishvili A.Sh., Davtyan K.V., Krivolapov S.N., Sokolov S.F., Lomidze N.N., Nechepurenko A.A., Okhotina E.N., Mikhaylov S.P., Artyukhina E.A., Batalov R.E., Lebedev D.S., Sagitov I.S., Khomutinin D.N. HEART RATE VARIABILITY AND CHOICE OF RATE-ADAPTIVE SENSOR IN PATIENTS WITH BRADYCARDIA-TACHYCARDIA SYNDROME. Journal of Arrhythmology. 2018;(93):5-16. (In Russ.) https://doi.org/ 10.25760/VA-2018-93-5-16.

Views: 188


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1561-8641 (Print)
ISSN 2658-7327 (Online)