Preview

Journal of Arrhythmology

Advanced search

Development of “false” atrioventricular block in a patient after heart transplantation: case report

https://doi.org/10.35336/VA-2023-1-10

Abstract

A clinical case of the development of bradycardia after heart transplantation is described. Electrocardiography data corresponded to atrioventricular (AV) block against the background of sinus bradycardia, which was the reason for the implantation of a pacemaker. Using intraprocedural electrophysiological study, the absence of data for AV dysfunction was revealed. The concept of AV block arose since the contracting part of the recipient’s atria was electrically isolated from the donor’s atria, there was no atrial activity in the donor heart, and the ventricles contracted due to AV node rhythm, which created the possibility for the presence of two dissociated rhythms.

About the Authors

E. A. Khomenko
Federal state budgetary scientific institution “Research institute for complex issues of cardiovascular diseases”
Russian Federation

Kemerovo, 6 Sosnoviy bvld.



S. E. Mamchur
Federal state budgetary scientific institution “Research institute for complex issues of cardiovascular diseases”
Russian Federation

 Kemerovo, 6 Sosnoviy bvld.



References

1. Mallidi HR, Bates M. Pacemaker Use Following Heart Transplantation. Ochsner J. 2017;17(1): 20-24.

2. Scott CD, Omar I, Mccomb JM, et al. Long term pacing in heart transplant recipients is usually unnecessary. Pace. 1991;14: 1792-6. https://doi.org/10.1111/j.1540-8159.1991.tb02768.x.

3. Scott CD, Dark JH, McComb JM. Sinus node function after cardiac transplantation. J Am Coll Cardiol. 1994;24: 1334-1341. https://doi.org/10.1016/0735-1097(94)90117-1.

4. Rowan RA, Billingham ME. Myocardial innervation in long-term heart transplant survivors a quantitative ultrastructural survey. J Heart Transplant. 1988;7: 448-52.

5. Mujamoto Y, Curtiss E, Kormos RL, et al. Bradyarrhythmia after heart transplantation: incidence, time course and outcome. Circulation. 1990;82(suppl IV): IV-313-7.

6. DiBiase A, Tse TM, Schnittger I, et al. Frequency and mechanism of bradycardia in cardiac transplant recipients and need for pacemakers. Am J Cardiol. 1991;67(16): 13851389. https://doi.org/10.1016/0002-9149(91)90469-2.

7. Woo GW, Schofield RS, Pauly DF, et al. Incidence, predictors, and outcomes of cardiac pacing after cardiac transplantation: an 11-year retrospective analysis. Transplantation. 2008;85(8): 1216-1218. https://doi.org/10.1097/TP.0b013e31816b677c.

8. Bacal F, Bocchi EA, Vieira ML, et al. Permanent and temporary pacemaker implantation after orthotopic heart transplantation. Arq Bras Cardiol. 2000;74: 9-12.

9. Bexton RS, Nathan AW, Hellestrand KJ, et al. The electrophysiologic characteristics of the transplanted heart. Am Heart J. 1984;107(1): 1-7. https://doi.org/10.1016/00028703(84)90124-8.

10. Thompson MA, Patel H. Posttransplant pacemaker placement: case series and review. Ochsner J. 2010;10(4): 236-40.

11. Mamchur SE, Malyshenko ES, Khomenko EA, et al. The Wolff-Parkinson-White syndrome of heart allograft and catheter ablation of accessory pathway after orthotopic heart transplantation. Complex Issues of Cardiovascular Diseases. 2014;4: 33-37 (In Russ.). https://doi.org/10.17802/2306-1278-2014-4-33-37.


Review

For citations:


Khomenko E.A., Mamchur S.E. Development of “false” atrioventricular block in a patient after heart transplantation: case report. Journal of Arrhythmology. 2023;30(1):е1-е5. https://doi.org/10.35336/VA-2023-1-10

Views: 325


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1561-8641 (Print)
ISSN 2658-7327 (Online)