Неадекватный шок подкожного дефибриллятора, обусловленный наличием остаточного воздуха в подкожном тоннеле
https://doi.org/10.35336/VA-2019-4-53-58
Аннотация
Об авторах
Е. Б. КропоткинРоссия
Кропоткин Евгений Борисович
Красноярск
Э. А. Иваницкий
Россия
Красноярск
А. Ю. Черемисина
Россия
Красноярск
О. В. Костылева
Россия
Москва
В. А. Сакович
Россия
Красноярск
Список литературы
1. Priori SG, Blomström-Lundqvist C, Mazzanti A, et al. ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Eur Heart J. 2015;36(41):2793-2867.
2. Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy. Ellenbogen K.A., Wilkoff B.L., Neal Kay G., et al. 5th edition. 2017.
3. Rusanov A., Spotnitz H M., A 15-Year Experience with Permanent Pacemaker and Defibrillator Lead and Patch Extractions. Ann Thorac Surg 2010; 89:44 -50.
4. Burke M.C., Gold M.R., Knight B.P., et al. Safety and Efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE Study and EFFORTLESS Registry. J Am Coll Cardiol 2015; 65: 1605-1615.
5. Chen CF, Jin CL, Liu MJ, Xu YZ. Efficacy, safety, and in-hospital outcomes of subcutaneous versus transvenous implantable defibrillator therapy: A meta-analysis and systematic review. Medicine (Baltimore). 2019;98(19):e15490.
6. Tachibana M, Nishii N, Banba K, et al. SMART pass will prevent inappropriate operation of S-ICD. J Arrhythm. 2018;35(1):86-91.
7. Ревишвили А.Ш., Неминущий Н.М., Баталов Р.Е., и соавт. Всероссийские клинические рекомендации по контролю над риском внезапной остановки сердца и внезапной сердечной смерти, профилактике и оказанию первой помощи. Вестник аритмологии. 2017. Т. 89. С. 2-104
8. Knops R.E., Olde Nordkamp L.R., de Groot, J.R. Wilde Arthur A.M. Two- incision technique for implantation of the subcutaneous implantable cardioverter-defibrillator. Heart Rhythm. 2013;10:1240-1243.
9. Kreis D.J., LiGalzi L., Shaw R.K. Air entrapment as a cause of transient cardiac pacemaker malfunction. Pacing Clin Electrphysiol. 1979;2:641-644.
10. Blackwell R.A., Rha-Waitze S.Y., Johnson A., et al. Failure of unipolar pacemaker secondary to subcutaneous emphysema. J Card Surg. 1997;12:282-3.
11. Santomauro M., Ferraro S., Maddalena G., et al. Pacemaker Malfunction Due to Subcutaneous Emphysema - A Case Report. Angiology. 1992;43: 873-976.
12. Melzer C., Witte H.J., Bauman G., et al. Transient Exit Block of a DDD Pacemaker with Unipolar Leads in Subcutaneous Emphysema Following Pneumothorax. PACE 2001; 24:893-894.
13. Swerdlow Ch., Asirvatham S., Ellenbogen K., et al. Troubleshooting Implantable Cardioverter-Defibrillator Sensing Problems I. Circ Arrhythm Electrophysiol. 2014;7:1237-1261.
14. Cheung J., Iwai S., Lerman B., et al. Shock-induced ventricular oversensing due to seal plug damage: A potential mechanism of inappropriate device therapies in implantable cardioverter-defibrillators. Heart Rhythm. 2005;2:1371-1375.
15. Ng K., Gould P. Acute transient non-physiological over-sensing in the ventricle with a DF4 lead. Indian Pacing and Electrophysiology Journal. 2015;15: 216-219.
16. Zipse M.M., Sauer W.H., Varosy P.D., et al. Inappropriate shocks due to subcutaneous air in a patient with a subcutaneous cardiac defibrillator. Circ Arrhythm Electrophysiol. 2014;7:768 - 770.
17. Taguchi Y., Ishikawa T., Matsumoto K., et al. An Inappropriate Shock Case Early after Implantation of a Subcutaneous Cardiac Defibrillator by Subcutaneous Entrapped Air. Int Heart J. 2018; 59: 417-419.
18. Yap S., Bhagwandien R.E., Szili-Torok T., et al. Air entrapment causing early inappropriate shocks in a patient with a subcutaneous cardioverter-defibrillator. Heart Rhythm. 2015;1:156 - 158.
19. Gamble J.H., Grogono J, Rajappan k. et al. Letter by Gamble, et al. Regarding Article, “Inappropriate Shocks due to Subcutaneous Air in a Patient With a Subcutaneous Cardiac Defibrillator” Circ Arrhythm Electrophysiol. 2014;7:1281.
20. Lee S., Souvaliotis N., Mehta D., et al. Inappropriate shock in a subcutaneous cardiac defibrillator due to residual air. Clin Case Rep. 2017;5:1203-1206.
21. Chinitz J.S., Nadraus P., Darge A., et al. Inappropriate Shocks within 24 hours after Implantation of a Subcutaneous Defibrillator with a Two-incision Technique. J of Innovations in Card Rhythm Manag. 2016;7:2295-2298.
22. Tachibana M, Nishii N, Banba K. SMART pass will prevent inappropriate operation of S-ICD. Journal of Arrhythmia. 2018;1-6.
Рецензия
Для цитирования:
Кропоткин Е.Б., Иваницкий Э.А., Черемисина А.Ю., Костылева О.В., Сакович В.А. Неадекватный шок подкожного дефибриллятора, обусловленный наличием остаточного воздуха в подкожном тоннеле. Вестник аритмологии. 2019;26(4):53-58. https://doi.org/10.35336/VA-2019-4-53-58
For citation:
Kropotkin E.B., Ivanitsky E.A., Cheremisina A.Yu., Kostyleva O.V., Sakovich V.A. Uncommon inappropriate shock of subcutaneous defibrillator in early postoperative period due to air in close proximity of shock electrode is presented. Journal of Arrhythmology. 2019;26(4):53-58. (In Russ.) https://doi.org/10.35336/VA-2019-4-53-58