Preview

Journal of Arrhythmology

Advanced search

HIGH-AMPLITUDE CARDIAC PACING IN ABLATION OF PARAHISIAL ECTOPIC ARRHYTHMIAS

Abstract

To assess effectiveness of high-amplitude cardiac pacing for prognosis of the risk of atrio-ventricular block in the course of radiofrequency ablation of parahisial ectopic foci, 20 patients aged38±14years (9 men/45% and 11 women/55%) without structural heart disease with ectopic foci located in the parahisial area were examined.

About the Authors

S. E. Mamchur
УРАМН «НИИ комплексных проблем сердечно-сосудистых заболеваний СО РАМН», Кемерово, Россия
Russian Federation


O. M. Chistyukhin
УРАМН «НИИ комплексных проблем сердечно-сосудистых заболеваний СО РАМН», Кемерово, Россия
Russian Federation


E. A. Khomenko
УРАМН «НИИ комплексных проблем сердечно-сосудистых заболеваний СО РАМН», Кемерово, Россия
Russian Federation


M. Yu. Kurilin
УРАМН «НИИ комплексных проблем сердечно-сосудистых заболеваний СО РАМН», Кемерово, Россия
Russian Federation


M. P. Romanova
УРАМН «НИИ комплексных проблем сердечно-сосудистых заболеваний СО РАМН», Кемерово, Россия
Russian Federation


References

1. Ehlert F.A., Goldberger J.J., Deal B.J. et al. Successful radiofrequency energy ablation of automatic junctional tachycardia preserving normal atrioventricular nodal conduction // Pacing Clin. Electrophysiol. - 1993. - Vol. 16. - P. 54-61.

2. Gaita F., Montefusco A., Riccardi R. et al. Acute and long-term outcome of transvenous cryothermal catheter ablation of supraventricular arrhythmias involving the perinodal region // J Cardiovasc. Med. (Hagerstown). - 2006.

3. Interventional electrophysiology / I. Singer, ed., 2nd ed. - Lippincott Williams & Wilkins, 2001. - 858 p.

4. Jackman W.M., Beckman K.J., McClelland J.H. et al. Parahisian pacing for differentiating retrograde conduction over septal parhway and AV node // Pacing Clin. Electrophysiol. - 1991. - Vol. 14. - P. 670 (Abstract).

5. Nadji G., Hermida J.S., Kubala M. et al. Cryoablation of junctional tachycardia at high risk of atrio-ventricular block // Arch. Cardiovasc. Dis. - 2008. - Vol. 101(3). - P. 149-154.

6. Heidbuchel H., Ector H., Adams J., Van de Werf F. Use of only a regular diagnostic His-bundle catheter for both fast and reproducible “para-Hisian pacing” and stable right ventricular pacing // J. Cardiovasc. Electrophysiol. - 1997. - Vol. 8. - P. 1121-1132.

7. Hirao K., Otomo K., Wang X. et al. Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over AV node // Circulation. - 1996. - Vol. 94. - P. 1027-1035.


Review

For citations:


Mamchur S.E., Chistyukhin O.M., Khomenko E.A., Kurilin M.Yu., Romanova M.P. HIGH-AMPLITUDE CARDIAC PACING IN ABLATION OF PARAHISIAL ECTOPIC ARRHYTHMIAS. Journal of Arrhythmology. 2010;61(61):26-29. (In Russ.)

Views: 128


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1561-8641 (Print)
ISSN 2658-7327 (Online)