Preview

Journal of Arrhythmology

Advanced search

RECENT ELECTRONIC IMPLANTATES FOR ELECTROCARDIOTHERAPY: NEW POTENTIALITIES OF DIAGNOSTICS AND OPTIMIZATION OF CARDIAC ACTIVITY

Abstract

Novel pacemaker diagnostic and curative potentialities of modern pacemakers connected with pacing using the closed circuit of control based on the stroke volume assessment and remote monitoring of the patient state are considered.

About the Author

I. Sh. Khasanov
Университет Эрланген-Нюрнберг им. Фридриха-Александра
Germany


References

1. Boheim G, SchaldachM. Rate-Responsive Pacemaker with Intracardiac Volume Feedback Control. BME-Austria 88, Graz, June 9-11,1988. Conference Proceedings: 116.

2. Schaldach M. PEP-gesteuerter Herzschrittmacher. // Biomed Technik 1989; 34:177-184.

3. Rushmer RF, Crystal DK, Wagner C, Ellis RM. Intracardiac Impedance Plethysmography. // Am J Physiol. 1953; 174 (1):171-174.

4. Baan J, Jong TTA, Kerkhof PLM et al. Continuous stroke volume and cardiac output from intraventricular dimensions obtained with impedance catheter. // Cardiovasc Res 1981; 15:328-334.

5. Lippert M, Zima E, Czygan G, Merkely B. Intracardiac impedance as hemodynamic sensor: feasibility study. //Biomed Technik 2003; 48 (Erganzungsband I): 248-249.

6. Schaldach M, Hutten H. Telecardiology-optimizing the diagnostic and therapeutic efficacy of the next implant generation. //Progress in Biomedical Research 1998; 3:1-4.

7. Wallbruck K, Stellbrink C, Santini M. et al. The Value of Permanent Follow-up of Implantable Pacemakers - FirstResults of an European Trial. // Biomed Tech (Berl) 47 (Suppi 1):950-953.

8. Scholten RIF, Thornton AS, Theuns DA et al. Twidler’s syndrome detected by Home Monitoring Device. // PACE 2004;27:1151-1152.

9. The Atrial Fibrillation Follow-up Investigation of Rkythm Management (AFFIRM) Investigators. A Comparison of Rate Control and Rhythm Control in Patients with Atrial Fibrillation. //New England Journal of Medicine 2002; 347 (23): 1825-1833.

10. Sweeney MO, Hellkamp AS, Ellenbogen KA et al. Circulation2003; 107 (23): 2932-2937.

11. Anosov O, Berdyshev S, Khassanov I. et al. Wave propagation in the atrial myocardium: Dispersion properties in the normal state and before fibrillation. IEEE Transactions on Biomedical Engineering 2002; 49 (12): 1642-1645.

12. Khassanov I, Anosov 0, Hensel B, Petersen S. Equivalent dispersion dependence - a new diagnostic algorithm concept for pacemakers. Progress in Biomedical Research 2004; 9 (1):11-15.


Review

For citations:


Khasanov I.Sh. RECENT ELECTRONIC IMPLANTATES FOR ELECTROCARDIOTHERAPY: NEW POTENTIALITIES OF DIAGNOSTICS AND OPTIMIZATION OF CARDIAC ACTIVITY. Journal of Arrhythmology. 2006;(44):66-70. (In Russ.)

Views: 195


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1561-8641 (Print)
ISSN 2658-7327 (Online)